Site Investigation For The Installation Restoration Program At Naval Air Station Glenview Illinois PDF Download

Are you looking for read ebook online? Search for your book and save it on your Kindle device, PC, phones or tablets. Download Site Investigation For The Installation Restoration Program At Naval Air Station Glenview Illinois PDF full book. Access full book title Site Investigation For The Installation Restoration Program At Naval Air Station Glenview Illinois.

Installation Restoration Program Site Investigation Report; 183rd Fighter Group, Illinois Air National Guard, Capital Airport, Springfield, Illinois

Installation Restoration Program Site Investigation Report; 183rd Fighter Group, Illinois Air National Guard, Capital Airport, Springfield, Illinois
Author: Earth technology corp oak ridge tn
Publisher:
Total Pages: 178
Release: 1996
Genre:
ISBN:

Download Installation Restoration Program Site Investigation Report; 183rd Fighter Group, Illinois Air National Guard, Capital Airport, Springfield, Illinois Book in PDF, ePub and Kindle

This Site Investigation (SI) Report documents activities The Earth Technology Corporation performed at the Illinois Air National Guard (ILANG), 183rd Fighter Group (FG), Capital Airport, Springfield, Illinois under the U.S. Department of Defense Installation Restoration Program. Two sites, Site 1 - Petroleum, Oil, and Lubricant (POL) Storage Area and Site 2 - Old Fire Training Area (FTA), were identified at ILANG, Capital Airport during the Preliminary Assessment (PA) begun by the Dynamac Corporation through the Hazardous Materials Technical Center and completed by Science and Technology in May 1990. Site 1 is located within the base boundaries, while Site 2 is located off-base on Springfield Airport Authority (SAA) property. The SI was conducted to: Confirm the presence or absence of contamination at the sites; Identify the sources and nature of contamination at the sites; Provide a preliminary assessment of the extent, magnitude, and movement of contamination; identify the potential threat of contamination to human health or the environment.


Installation Restoration Program, Technical Memorandum for Field Investigation at IRP Sites No. 1 and No. 2, Vol 1, 183rd Fighter Wing, Illinois Air National Guard, Capital Municipal Airport, Springfield, Illinois

Installation Restoration Program, Technical Memorandum for Field Investigation at IRP Sites No. 1 and No. 2, Vol 1, 183rd Fighter Wing, Illinois Air National Guard, Capital Municipal Airport, Springfield, Illinois
Author:
Publisher:
Total Pages: 67
Release: 1997
Genre:
ISBN:

Download Installation Restoration Program, Technical Memorandum for Field Investigation at IRP Sites No. 1 and No. 2, Vol 1, 183rd Fighter Wing, Illinois Air National Guard, Capital Municipal Airport, Springfield, Illinois Book in PDF, ePub and Kindle

The Installation Restoration Program was initiated by the Air National Guard (ANG) to evaluate potential contamination to the environment caused by past practices at its installations. Two sites were identified at Capital Municipal Airport during the 1990 Preliminary Assessment; the Petroleum, Oils and Lubricants Storage Area (Site 1) and the Old Fire Training Area (Site 2). Information gathered during a 1996 Site Investigation on both sites and 1995 Site Investigation Addendum for Site 2 did not provide adequate information for decision-making. This Field Investigation was designed to fill data gaps. The Tech Memo recommends Site 1 proceed to a No Further Action Decision Document, and Site 2 proceed to an Engineering Evaluation/Cost Analysis (EE/CA). No further field effort is necessary to complete the EE/CA. Vol 1 contains the main text of the report. Vol 2 contains the supporting data.


Installation Restoration Program. Site Investigation Report. Volume 2: Appendices. 183rd Fighter Group, Illinois Air National Guard, Capital Airport, Springfield, Illinois

Installation Restoration Program. Site Investigation Report. Volume 2: Appendices. 183rd Fighter Group, Illinois Air National Guard, Capital Airport, Springfield, Illinois
Author: MARTIN MARIETTA ENERGY SYSTEMS INC OAK RIDGE TN.
Publisher:
Total Pages: 755
Release: 1996
Genre:
ISBN:

Download Installation Restoration Program. Site Investigation Report. Volume 2: Appendices. 183rd Fighter Group, Illinois Air National Guard, Capital Airport, Springfield, Illinois Book in PDF, ePub and Kindle

Site Investigation Report, Illinois Air National Guard, 183rd Fighter Group, Capital Airport, Springfield, Illinois, Volume II - Appendices. This is the second volume of a two volume site investigation report. Two sites (Site 1 - POL Storage Area, and Site 2 - Old Fire Training Area) were investigated under the Installation Restoration Program. Soil and groundwater samples were collected from both sites and analyzed. Surface water and sediment samples were collected from Site 2 and analyzed. Monitoring of the dissolved hydrocarbon plume using existing monitoring wells was recommended for Site 1. A Remedial Investigation to define the nature and extent of soil and groundwater contamination was recommended for Site 2.


Installation Restoration Program (IRP). Proposed Plan for Operable Unit 2. Naval Air Station Pensacola

Installation Restoration Program (IRP). Proposed Plan for Operable Unit 2. Naval Air Station Pensacola
Author:
Publisher:
Total Pages: 20
Release: 2008
Genre:
ISBN:

Download Installation Restoration Program (IRP). Proposed Plan for Operable Unit 2. Naval Air Station Pensacola Book in PDF, ePub and Kindle

This document provides background information for the proposed environmental remediation of the sites included in Operable Unit 2. The plan explains the investigation of the sites and the alternative cleanup methods being explored.


Installation Restoration Program. Site Investigation Report, IRP Sites No. 1, No. 2, and No. 3. 106th Civil Engineering Flight, New York Air National Guard, Roslyn Air National Guard Station, Roslyn, New York

Installation Restoration Program. Site Investigation Report, IRP Sites No. 1, No. 2, and No. 3. 106th Civil Engineering Flight, New York Air National Guard, Roslyn Air National Guard Station, Roslyn, New York
Author:
Publisher:
Total Pages: 164
Release: 1996
Genre:
ISBN:

Download Installation Restoration Program. Site Investigation Report, IRP Sites No. 1, No. 2, and No. 3. 106th Civil Engineering Flight, New York Air National Guard, Roslyn Air National Guard Station, Roslyn, New York Book in PDF, ePub and Kindle

This report presents the results of the Site Investigation (SI) conducted at IRP Sites No. 1, No. 2, and No. 3 at the 106th Civil Engineering Flight (CEF) located at Roslyn Air National Guard Station (ANGS), Roslyn, long Island, New York. A Preliminary Assessment (PA) of the 106th CEF was published by Science and Technology, Inc., in February 1991. The PA resulted in the identification of two potentially contaminated waste holding areas and a waste sludge application site. These sites were identified as IRP Site No. 1 (Access Road to Aerospace Ground Equipment 'AGE' Shop), IRP Site No. 2 (Old Waste Holding Area No. 1), and IRP Site No. 3 (Old Waste Holding Area No. 2) and recommended for further investigation under the Installation Restoration Program (IRP).


Installation Restoration Program, Technical Memorandum for Field Investigation at IRP Sites No. 1 and No. 2, Vol 2, 183rd Fighter Wing, Illinois Air National Guard, Capital Municipal Airport, Springfield, Illinois, Appendices A - J.

Installation Restoration Program, Technical Memorandum for Field Investigation at IRP Sites No. 1 and No. 2, Vol 2, 183rd Fighter Wing, Illinois Air National Guard, Capital Municipal Airport, Springfield, Illinois, Appendices A - J.
Author:
Publisher:
Total Pages: 426
Release: 1997
Genre:
ISBN:

Download Installation Restoration Program, Technical Memorandum for Field Investigation at IRP Sites No. 1 and No. 2, Vol 2, 183rd Fighter Wing, Illinois Air National Guard, Capital Municipal Airport, Springfield, Illinois, Appendices A - J. Book in PDF, ePub and Kindle

The Installation Restoration Program was initiated by the Air National Guard (ANG) to evaluate potential contamination to the environment caused by past practices at its installations. Two sites were identified at Capital Municipal Airport during the 1990 Preliminary Assessment; the Petroleum, Oils and Lubricants Storage Area (Site 1) and the Old Fire Training Area (Site 2). Information gathered during a 1996 Site Investigation on both sites and 1995 Site Investigation Addendum for Site 2 did not provide adequate information for decision-making. This Field Investigation was designed to fill data gaps. The Tech Memo recommends Site 1 proceed to a No Further Action Decision Document, and Site 2 proceed to an Engineering Evaluation/Cost Analysis (EE/CA). No further field effort is necessary to complete the EE/CA. Vol 1 contains the main text of the report. Vol 2 contains the supporting data.