Seismic Response Of Base Isolated Buildings Considering Pounding To Moat Walls PDF Download

Are you looking for read ebook online? Search for your book and save it on your Kindle device, PC, phones or tablets. Download Seismic Response Of Base Isolated Buildings Considering Pounding To Moat Walls PDF full book. Access full book title Seismic Response Of Base Isolated Buildings Considering Pounding To Moat Walls.

Seismic Response of Base Isolated Buildings Considering Pounding to Moat Walls

Seismic Response of Base Isolated Buildings Considering Pounding to Moat Walls
Author: Armin Masroor Shalmani
Publisher:
Total Pages: 254
Release: 2013
Genre:
ISBN:

Download Seismic Response of Base Isolated Buildings Considering Pounding to Moat Walls Book in PDF, ePub and Kindle

Seismic isolation offers a simple and direct opportunity to control or even eliminate damage to structures subjected to ground shaking by simultaneously reducing deformations and acceleration demands. A base isolation system decouples the superstructure from the ground resulting in elongation of fundamental period of the structure and reducing the accelerations transferred to superstructure during ground shaking. However, increasing the fundamental period of the structure is mostly accompanied by increased displacement demands. In base isolated structures, this large displacement is concentrated at base level where seismic isolation devices are installed and designed to handle these large deformations without damage. A typical base isolated basement design requires a space in which the building is free to move sideways without hitting the surrounding structure. This space is commonly referred to as the "moat". Structural design codes such as ASCE 7-05 that regulate the design of buildings incorporating seismic base isolation systems require the minimum moat wall clearance distance equal to the maximum displacement at the base of the structure under the Maximum Considered Earthquake (MCE), although the superstructure is designed for design basis earthquake (DBE) level. Despite the cautious regulation for moat wall gap distance, pounding of base isolated buildings to moat walls has been reported in previous earthquakes. In conventional structures, the pounding problem between adjacent structures of buildings and highway bridges has been a major cause of seismic damage, even collapse, during earthquakes in the past several decades. Current design specifications may not adequately account for the large forces generated during impact in base isolated buildings. This study investigates the pounding phenomenon in base isolated buildings from both experimental and analytical perspectives by conducting shake table pounding experiments, developing effective models for impact to moat walls and evaluating the adequacy of code specifications for the gap distance of moat walls. A series of prototype base isolated moment and braced buildings designed by professional engineers for the purpose of this project is presented and one of the models was selected for a quarter scale shake table test with moat walls. The pounding experiments indicate that the contact forces generated during pounding can induce yielding in the superstructure and amplify the response acceleration at all stories of the building. The response amplification and damage depends on the gap distance, moat wall properties, and impact velocity. A detailed finite element model of the test setup is developed in OpenSees. An analytical study on the dynamic behavior of the moat walls resulted in proposing a new impact element. Numerical simulation using the proposed impact element compares well with experimental results. A series of collapse studies using the Methodology in FEMA P695 was conducted for both prototype models at various gap distances. The collapse probability of base isolated models used in this study and the effect of moat wall gap distance on the probability of collapse for base isolated structures is investigated. These studies verify that pounding to moat walls at the required gap distance by ASCE7-05 result in acceptable probability of collapse for the flexible and ductile moment frame models examined. However, the braced frame shows a notable drop in collapse margin ratio because of pounding to moat wall at the required gap distance and requires increasing the gap distance by 17%. to have an acceptable collapse probability.


Seismic Response of Base Isolated Buildings Considering Pounding to Moat Walls

Seismic Response of Base Isolated Buildings Considering Pounding to Moat Walls
Author: Armin Masroor
Publisher:
Total Pages: 264
Release: 2013
Genre: Buildings
ISBN:

Download Seismic Response of Base Isolated Buildings Considering Pounding to Moat Walls Book in PDF, ePub and Kindle

This study investigates the pounding phenomenon in base isolated buildings by conducting shake table pounding experiments, developing analytical models for impact to moat walls, and evaluating the adequacy of code specifications for the gap distance of moat walls. The experiments indicated that the contact forces generated during pounding can induce yielding in the superstructure and amplify the response acceleration at all stories of the building. The response amplification and damage depends on the gap distance, moat wall properties, and impact velocity. A detailed finite element model of the test setup was developed in OpenSees and an analytical study on the dynamic behavior of the moat walls resulted in proposing a new impact element. The numerical simulation showed good agreement with the experimental results. Finally, a series of collapse studies using the FEMA P695 methodology was conducted to determine the collapse probability of the base isolated models and the effect of moat wall gap distance on the probability of collapse. These studies verified that pounding to moat walls at the gap distance required by ASCE7-05 results in an acceptable probability of collapse for flexible and ductile moment frame models. However, the braced frame showed a notable drop in collapse margin ratio because of pounding to the moat wall at the required gap distance and requires increasing the gap distance by 17%.to achieve an acceptable collapse probability.


Pounding and Impact of Base Isolated Buildings Due to Earthquakes

Pounding and Impact of Base Isolated Buildings Due to Earthquakes
Author: Vivek Kumar Agarwal
Publisher:
Total Pages:
Release: 2005
Genre:
ISBN:

Download Pounding and Impact of Base Isolated Buildings Due to Earthquakes Book in PDF, ePub and Kindle

As the cost of land in cities increases, the need to build multistory buildings in close proximity to each other also increases. Sometimes, construction materials, other objects and any projections from a building may also decrease the spacing provided between the buildings. This leads to the problem of pounding of these closely placed buildings when responding to earthquake ground motion. The recent advent of base isolation systems and their use as an efficient earthquake force resisting mechanism has led to their increased use in civil engineering structures. At the same time, building codes that reflect best design practice are also evolving. The movement of these base isolated buildings can also result in building pounding. Since base isolation is itself a relatively new technique, pounding phenomenon in base isolated buildings have not been adequately investigated to date. This study looks at the base isolated response of a single two story building and adjacent two story building systems. Four earthquakes with increasing intensity were used in this study. It was found that it is difficult to anticipate the response of the adjacent buildings due to non- linear behavior of pounding and base isolation. The worst case for pounding was found to occur when a fixed base and base isolated buildings were adjacent to each other.