Floodplain Assessment For The Proposed Engineered Erosion Controls At Ta 72 In Lower Sandia Canyon Los Alamos National Laboratory PDF Download

Are you looking for read ebook online? Search for your book and save it on your Kindle device, PC, phones or tablets. Download Floodplain Assessment For The Proposed Engineered Erosion Controls At Ta 72 In Lower Sandia Canyon Los Alamos National Laboratory PDF full book. Access full book title Floodplain Assessment For The Proposed Engineered Erosion Controls At Ta 72 In Lower Sandia Canyon Los Alamos National Laboratory.

Floodplain Assessment for the Proposed Engineered Erosion Controls at TA-72 in Lower Sandia Canyon, Los Alamos National Laboratory

Floodplain Assessment for the Proposed Engineered Erosion Controls at TA-72 in Lower Sandia Canyon, Los Alamos National Laboratory
Author:
Publisher:
Total Pages:
Release: 2012
Genre:
ISBN:

Download Floodplain Assessment for the Proposed Engineered Erosion Controls at TA-72 in Lower Sandia Canyon, Los Alamos National Laboratory Book in PDF, ePub and Kindle

Los Alamos National Laboratory (LANL) is preparing to implement engineering controls in Sandia Canyon at Technical Area (TA) 72. Los Alamos National Security (LANS) biologists conducted a floodplain determination and this project is located within a 100-year floodplain. The proposed project is to rehabilitate the degraded channel in lower Sandia Canyon where it crosses through the outdoor firing range at TA-72 to limit the loss of sediment and dissipate floodwater leaving LANL property (Figure 1). The proposed construction of these engineered controls is part of the New Mexico Environment Department's (NMED) approved LANL Individual Storm Water Permit. The purpose of this project is to install storm water controls at Sandia Watershed Site Monitoring Area 6 (S-SMA-6). Storm water controls will be designed and installed to meet the requirements of NPDES Permit No. NM0030759, commonly referred to as the LANL Individual Storm Water Permit (IP). The storm water control measures address storm water mitigation for the area within the boundary of Area of Concern (AOC) 72-001. This action meets the requirements of the IP for S-SMA-6 for storm water controls by a combination of: preventing exposure of upstream storm water and storm water generated within the channel to the AOC and totally retaining storm water falling outside the channel but within the AOC.


Floodplain and Wetland Assessment for the Mortandad Wetland Enhancement and the DP Dissipater Projects at Los Alamos National Laboratory

Floodplain and Wetland Assessment for the Mortandad Wetland Enhancement and the DP Dissipater Projects at Los Alamos National Laboratory
Author:
Publisher:
Total Pages: 15
Release: 2017
Genre:
ISBN:

Download Floodplain and Wetland Assessment for the Mortandad Wetland Enhancement and the DP Dissipater Projects at Los Alamos National Laboratory Book in PDF, ePub and Kindle

This floodplain and wetland assessment was prepared in accordance with 10 Code of Federal Regulations (CFR) 1022 Compliance with Floodplain and Wetland Environmental Review Requirements, which was promulgated to implement the U.S. Department of Energy (DOE) requirements under Executive Order 11988 Floodplain Management and Executive Order 11990 Wetlands Protection. According to 10 CFR 1022, a 100-year floodplain is defined as "the lowlands adjoining inland and coastal waters and relatively flat areas and flood prone areas of offshore islands" and a wetland is defined as "an area that is inundated or saturated by surface or groundwater at a frequency and duration sufficient to support, and that under normal circumstances does support, a prevalence of vegetation typically adapted for life in saturated soil conditions, including swamps, marshes, bogs, and similar areas." In this action, DOE is proposing two projects to improve wetland and floodplain function at Los Alamos National Laboratory (LANL). The proposed work will comply with corrective action requirements under the Settlement Agreement and Stipulated Final Compliance Order (Settlement Agreement)1 Number HWB-14-20. The first project is located in Technical Areas (TA)-03 in upper Mortandad Canyon. The upper Mortandad wetlands have existing stormwater controls that need to be rehabilitated. Head-cut formation is occurring at the downstream portion of the wetland. This project will repair damages to the wetland and reduce the future erosion potential. The second project is located in TA-21 in Delta Prime (DP) Canyon. The intent of the DP Dissipater Project in DP Canyon is to install stormwater control structures in DP Canyon to retain low channel flows and reduce downstream sediment transport as well as peak flows during low and moderate storm events. Due to increased erosion, the stream bank in this area has unstable vertical walls within the stream channel. The DOE prepared this floodplain and wetland assessment to evaluate the potential impacts of implementing the proposed actions within the wetland and floodplain, as required by 10 CFR 1022.


Floodplain Statement of Findings for Corrective Actions in Potrillo Canyon Technical Area-36, Los Alamos National Laboratory, Los Alamos, New Mexico

Floodplain Statement of Findings for Corrective Actions in Potrillo Canyon Technical Area-36, Los Alamos National Laboratory, Los Alamos, New Mexico
Author:
Publisher:
Total Pages: 5
Release: 2016
Genre:
ISBN:

Download Floodplain Statement of Findings for Corrective Actions in Potrillo Canyon Technical Area-36, Los Alamos National Laboratory, Los Alamos, New Mexico Book in PDF, ePub and Kindle

In 2014, baseline storm water monitoring samples for Potrillo Canyon Sample Management Area (Figure 1) at Los Alamos National Laboratory (LANL) exceeded the National Pollutant Discharge Elimination System Individual Permit No. NM0030759 target action level (TAL) of 15 picocuries per liter (pCi/L) for gross-alpha radioactivity (393 pCi/L) and a TAL of 30 pCi/L for radium-226 and radium-228 (95.9 pCi/L). Consequently, erosion control measures within the management area are proposed to minimize sediment migration, a corrective action under the permit that is a requirement of the New Mexico Environment Department consent decree and a good management practice to limit off site sediment migration. The area proposed for erosion controls (Figure 1) consists of portions of Technical Area 36 that were used as firing sites primarily involved high explosives (HE) and metal (e.g., depleted uranium, lead, copper, aluminum, and steel), small-explosives experiments and burn pits (burn pits were used for burning and disposal of test debris). In addition, underground explosive tests were conducted at an approximate depth of 100 feet were also conducted. These watershed-based storm water controls will focus on addressing erosion occurring within the floodplain through mitigating and reducing both current and future channelization and head cutting.


Monitored Natural Attenuation of Inorganic Contaminants in Ground Water

Monitored Natural Attenuation of Inorganic Contaminants in Ground Water
Author:
Publisher:
Total Pages: 124
Release: 2007
Genre: Arsenic
ISBN:

Download Monitored Natural Attenuation of Inorganic Contaminants in Ground Water Book in PDF, ePub and Kindle

V.3 ... consists of individual chapters that describe 1) the conceptual background for radionuclides, including tritium, radon, strontium, technetium, uranium, iodine, radium, thorium, cesium, plutonium-americium and 2) data requirements to be met during site characterization.


Complex Cleanup

Complex Cleanup
Author:
Publisher:
Total Pages: 34
Release: 1991
Genre: Government publications
ISBN:

Download Complex Cleanup Book in PDF, ePub and Kindle