Flexural Behavior Of Steel Fiber Reinforced Prestressed Concrete Beams And Double Punch Test For Fiber Reinforced Concrete PDF Download

Are you looking for read ebook online? Search for your book and save it on your Kindle device, PC, phones or tablets. Download Flexural Behavior Of Steel Fiber Reinforced Prestressed Concrete Beams And Double Punch Test For Fiber Reinforced Concrete PDF full book. Access full book title Flexural Behavior Of Steel Fiber Reinforced Prestressed Concrete Beams And Double Punch Test For Fiber Reinforced Concrete.

Flexural Behavior of Steel Fiber Reinforced Prestressed Concrete Beams and Double Punch Test for Fiber Reinforced Concrete

Flexural Behavior of Steel Fiber Reinforced Prestressed Concrete Beams and Double Punch Test for Fiber Reinforced Concrete
Author: Netra Bahadur Karki
Publisher:
Total Pages:
Release: 2012
Genre: Fiber-reinforced concrete
ISBN:

Download Flexural Behavior of Steel Fiber Reinforced Prestressed Concrete Beams and Double Punch Test for Fiber Reinforced Concrete Book in PDF, ePub and Kindle

Steel fibers have widely been used in the past to reinforce brittle materials in many nonstructural applications such as pavement, tunneling lining, etc. On the basis of numerous previous studies, ACI 318-11 [2011] has recently accepted steel fiber as a minimum shear reinforcement replacement with minimum 0.75% volume fraction for both reinforced concrete and prestressed concrete members. However, not much previous research has talked about the flexural behavior of fiber reinforced concrete (FRC). As per ACI 318-11 for tension-controlled sections, the net tensile strains in the outermost layer of steel, et, should be greater than or equal to 0.005 and for the moment redistribution in continuous beam the section should sufficiently ductile (et [greater or equal to] 0.0075). For this, the sections should have small longitudinal reinforcement ratio which ultimately leads to an inefficient beam section with a large cross-sectional area. In contrast, the use of smaller concrete cross sections can lead to a diminished ductile flexural behavior as well as premature shear failure. In this context, the use of steel fiber reinforced concrete could be a potential solution since fiber can increase both the concrete shear strength and it's usable compressive strains. However limited previous researches on the flexural behavior on SFRC beams are available and most of them are of small scales and concentrated only basically for shear behavior. To the best of our knowledge, the large-scale prestressed fiber reinforced concrete beam specimens have yet to be studied for flexure behavior. In this project, six large scale prestressed concrete beams with or without steel fiber along with some material test were tested. Our experimental investigations indicated that even with inclusion of small percentage volume of fraction of steel fiber (Vf =0.75%) could not only increase the ductility and shear strength of the SFRPC beam but also change the failure pattern by increasing usable strain in concrete and steel. A modification on the limit for c/dt ratio and [phi] factor for design of flexural member given in current ACI could be proposed which could imply the smaller sections with higher longitudinal reinforcement ratio and less shear reinforcement. could be used. Any standard material test results have to ensure that FRC has, at least, been batched properly and it can give indications of probable performance when used in structures. In the current material testing method suggested by ACI, the third point bending test (ASTM C1609) has an inherent problem in that the coefficients of variations for post cracking strength and residual strength are generally very high on the order of 20%. The direct tensile test can be a more appropriate material. However, it is currently not recommended as standard method in the U.S. Because of it's difficultly in gripping arrangement which will lead to cracking of the specimen at the grips. Both the test methods also require close loop servo controlled machine. The round panel test method (ASTM C1550) requires large size specimen and heavy steel supports prevents performing test in small laboratories. Split cylinder test (ASTM C496), do not necessarily reflect the true properties of the material as the specimen is forced to fail in the line of the application of the load and the test method is also not recommended by ACI for SFRC. In order to improve the material assessment procedure, the double Punch Test (DPT) introduced by Chen in 1970 [Chen, 1970] was extensively evaluated to develop a simple, quick and reliable testing method for SFRC. Various tests were carried out in order to evaluate peak and residual strength, stiffness, strain hardening and softening, toughness and other post crack properties. Our test results indicated that the DPT method could be immersed as reliable, easier and economical material test method. It could be used to distinguish the peak strength, residual strength, toughness stiffness and crack resistance, of different SFRC mixtures with less scatter results compared to other material test methods.


Double-punch Test for Evaluating the Performance of Steel Fiber-reinforced Concrete

Double-punch Test for Evaluating the Performance of Steel Fiber-reinforced Concrete
Author: Aaron Paul Woods
Publisher:
Total Pages: 386
Release: 2012
Genre:
ISBN:

Download Double-punch Test for Evaluating the Performance of Steel Fiber-reinforced Concrete Book in PDF, ePub and Kindle

The objective of this study is to develop test protocols for comparing the effectiveness of fiber-reinforced concrete (FRC) mixtures with high-performance steel fibers. Steel fibers can be added to fresh concrete to increase the tensile strength, ductility, and durability of concrete structures. In order to quantify steel fiber-reinforced concrete (SFRC) mixtures for field applications, a material test capable of predicting the performance of SFRC for field loading conditions is required. However, current test methods used to evaluate the structural properties of FRC (such as residual strength and toughness) are widely regarded as inadequate; a simple, accurate, and consistent test method is needed. It was determined that the Double-Punch Test (DPT), originally introduced by Chen in 1970 for plain concrete, could be extended to fiber-reinforced concrete to satisfy this industry need. In the DPT, a concrete cylinder is placed vertically between the loading platens of the test machine and compressed by two steel punches located concentrically on the top and bottom surfaces of the cylinder. It is hypothesized that the Double-Punch Test is capable of comparing future fiber-reinforcement design options for use in structural applications, and is suitable for evaluating FRC in general. The DPT Research and Testing Program was administered to produce sufficient within-laboratory data to make conclusions and recommendations regarding the simplicity, reliability, and reproducibility of the DPT for evaluating the performance of SFRC. Several variables (including fiber manufacturer, fiber content, and testing equipment) were evaluated to verify the relevance of the DPT for FRC. In this thesis, the results of 120 Double-Punch Tests are summarized and protocols for its effective application to fiber-reinforced concrete are recommended. Also, fundamental data is provided that indicates the DPT could be standardized by national and international agencies, such as the American Society of Testing and Materials (ASTM), as a method to evaluate the mechanical behavior of FRC. This project is sponsored by the Texas Department of Transportation (TxDOT) through TxDOT Project 6348, "Controlling Cracking in Prestressed Concrete Panels and Optimizing Bridge Deck Reinforcing Steel," which is aimed at improving bridge deck construction through developments in design details, durability, and quality control procedures.


ACI Structural Journal

ACI Structural Journal
Author:
Publisher:
Total Pages: 792
Release: 1988
Genre: Concrete
ISBN:

Download ACI Structural Journal Book in PDF, ePub and Kindle