Are you looking for read ebook online? Search for your book and save it on your Kindle device, PC, phones or tablets. Download Field Monitoring Of Shrinkage Cracking Potential In A High Performance Bridge Deck PDF full book. Access full book title Field Monitoring Of Shrinkage Cracking Potential In A High Performance Bridge Deck.

Field Monitoring of Shrinkage Cracking Potential in a High-performance Bridge Deck

Field Monitoring of Shrinkage Cracking Potential in a High-performance Bridge Deck
Author: Timothy Walkowich
Publisher:
Total Pages: 107
Release: 2011
Genre: Bridges
ISBN:

Download Field Monitoring of Shrinkage Cracking Potential in a High-performance Bridge Deck Book in PDF, ePub and Kindle

Over the past decade many state engineers throughout New Jersey have reported cracking on High Performance Concrete (HPC) bridge decks at early ages. The presence of cracking early in the life of a high performance deck offsets the benefits gained in using the material as the potential for corrosion begins at the onset of cracking. While many factors apply to bridge deck cracking, the shrinkage of the concrete's mass is a primary concern. Because of shear studs and boundary conditions, among other causes that act in restraining the deck itself, it is important to understand the mechanics of concrete under restraint. The AASHTO Passive Ring Test (PP 34-06) is seeing an increase in use in studies analyzing restrained shrinkage. The test simulates a concrete member of infinite length and allows researchers to study the effects of various parameters on restrained shrinkage. This thesis presents the results of a study that analyzed the ring test's ability to simulate restrained shrinkage on HPC bridge decks. The investigation incorporated an instrumented, simply supported composite bridge deck with laboratory samples taken on the day of the pour as well as a finite element analysis. The results suggest the AASHTO Passive Ring Test simulates the restrained shrinkage of simply supported HPC decks reasonably well. Fewer than 1% of all cracking present on the ring specimens saw complete penetration through the sample with 80-90% of all cracking considered to be micro cracking. While the presence of several cracks along the bridge deck itself showed no correlation with the shrinkage ring specimens, finite element analysis suggests these cracks are a result of adjacent live load. Also, the findings of this study highlight the importance of following design in the field as well as the effect of live load on staged construction of HPC bridge decks.


Phase 1 Report on the Development of Predictive Model for Bridge Deck Cracking and Strength Development

Phase 1 Report on the Development of Predictive Model for Bridge Deck Cracking and Strength Development
Author:
Publisher:
Total Pages: 64
Release: 2009
Genre: Bridges
ISBN:

Download Phase 1 Report on the Development of Predictive Model for Bridge Deck Cracking and Strength Development Book in PDF, ePub and Kindle

Early-age cracking, typically caused by drying shrinkage (and often coupled with autogenous and thermal shrinkage), can have several detrimental effects on long-term behavior and durability. Cracking can also provide ingress of water that can drive chemical reactions, such as alkali-silica reaction (ASR) and sulfate attack. Because of the problems associated with cracking observed in bridge decks, and the impact of early-age cracking on long-term performance and durability, it is imperative that bridge decks be constructed with minimal early-age cracking and that exhibit satisfactory long-term performance and durability. To achieve these goals for bridges in the state of Texas, a research team has been assembled that possesses significant expertise and background in cement chemistry, concrete materials and durability, structural performance, computational mechanics (finite difference/element), bridge deck construction and maintenance, monitoring of in-site behavior of field structures, and the development of test methods and specifications aimed at practical implementation by state highway departments. This proposal describes a laboratory- and field-based research program aimed at developing a bridge deck cracking model that will ultimately be integrated into ConcreteWorks, a suite of software programs developed for TxDOT by this same research team.


Assessment of Cracking Potential of High-performance Concrete Due to Restrained Shrinkage

Assessment of Cracking Potential of High-performance Concrete Due to Restrained Shrinkage
Author:
Publisher:
Total Pages: 146
Release: 2007
Genre: Concrete
ISBN:

Download Assessment of Cracking Potential of High-performance Concrete Due to Restrained Shrinkage Book in PDF, ePub and Kindle

Many State Engineers have observed that a number of high-performance concrete (HPC) bridge decks exhibited cracking and sometimes soon after being poured. Although deck cracking can be attributed to various causes, in many cases, concrete shrinkage is considered the main contributor. Additionally, concrete in bridge decks is considered restrained and there is a need to examine the behavior of HPC mixes under those conditions. The AASHTO test (PP 34-06, The Passive or Restrained Ring Test) is employed to measure the cracking potential and restrained shrinkage behavior of various HPC mixes used in bridge deck projects contracted by the New Jersey Department of Transportation (NJDOT). This thesis presents the results of a study which utilized a method for directly measuring the strain development in the concrete ring using Vibrating Wire Strain Gages (VWSG). For each mix, additional tests were performed to determine the corresponding mechanical properties (e.g., elastic modulus, tensile splitting strength, compressive strength, etc.). The effect of total amount of cementitious materials and the potential of cracking for various mixes are also reported. The results of the study are used to correlate strains from restrained shrinkage tests with those from free shrinkage tests. Results show that the coarse aggregate (CA) content, the coarse/fine aggregate ratio, and cementitious content have the greatest effect on both free and restrained shrinkage. Mixes with higher cementitious content were observed to crack earlier. In general, to minimize HPC cracking potential, it is suggested that a limit on free shrinkage (450 micro strain at 56 days) be specified in bridge decks to indirectly reflect restrained shrinkage conditions. Additional limits for the total amount of coarse aggregate (1800 lb/cu yd.) and Coarse/Fine aggregate ratio (1.48) should also be considered.


Improving Service Life of Concrete Structures Through the Use of Internal Curing

Improving Service Life of Concrete Structures Through the Use of Internal Curing
Author: Timothy J. Barrett
Publisher:
Total Pages: 483
Release: 2015
Genre: Concrete
ISBN:

Download Improving Service Life of Concrete Structures Through the Use of Internal Curing Book in PDF, ePub and Kindle

The Indiana Department of Transportation (INDOT) commissioned the construction of six bridge decks utilizing a new class of internally cured high performance concrete (IC HPC). The first four bridge decks were constructed in the summer of 2013, while the fifth was built in November of 2014 and the sixth is planned for the summer of 2015. These decks implement research findings presented in the FHWA/IN/JTRP-2010/10 report (Schlitter, Henkensiefken, et al. 2010) where internal curing was proposed as one method to reduce the potential for shrinkage cracking, leading to improved durability. In addition, the use of higher performance concrete mixtures and a new specification composed of prescriptive and performance based measures was implemented with the intention of extending the service life of the bridge decks. The objectives of this thesis are to provide documentation of the construction and performance of the IC HPC bridge decks cast in Indiana and provide a viable, practice-ready method for the assessment of the potential durability of these concretes. In fulfillment of these objectives, samples of the IC HPC used in construction were compared to a reference high performance concrete (HPC) which did not utilize internal curing and was made by the same producer with the same constituent materials. The samples collected in the field were transported to the laboratory where the mechanical performance, resistance to chloride ingress, and potential for shrinkage and cracking was assessed. Using experimental results and mixture proportions, the diffusion based service life of the bridge decks was able to be estimated. The construction process was documented for first four bridge decks made using internal cured high performance concrete (IC HPC). These concretes were able to be designed, batched, and placed and are now in service. While avoidable issues were observed during batching construction related to corrections of batching water, batching tolerances and fluctuations in air content (which apply to any concrete), the IC HPC was able to be batched and placed using slight modifications to conventional methods. The production of the IC HPC mixtures was implemented using a mixed specification using prescriptive and performance based measures representing an improvement on previous specifications which did not specifically have provisions that consider durability. To aid in the implementation of internal curing in the field, a new quality control technique for lightweight aggregate utilizing a centrifuge has been implemented is now standardized in Indiana Testing Method 222 (Miller, Barrett, et al. 2014). The results of laboratory testing indicate that the compressive strength, modulus of elasticity, and tensile strength of the IC HPC mixtures was not substantially different than the HPC mixtures and as such current codified equations are able to be used to predict the modulus of elasticity and tensile strength if the compressive strength is known. The diffusion of chlorides in these concretes was assessed, where it was shown that each of the mixtures tested had a charge passed in the rapid chloride permeability test of less than 1500 C at 91 days (AASHTO T277-07 2007); additional testing provided equivalent results when performing the Nordtest (NT Build 492 1999), Stadium migration test , or electrical resistivity test. Using experimental results which determined the chloride diffusion and permeability, the diffusion based service life of the IC HPC bridge decks was estimated to be between approximately 60 to 90 years, compared to approximately 18 years for the conventional class C bridge deck concrete used in Indiana. The susceptibility to early age shrinkage and cracking was evaluated where it was shown that IC HPC concretes exhibited a reduction in early age shrinkage of 70 to 90%, resulting in a reduction in residual stresses of 80% or more while reducing thermally induced stress by up to 55% when compared to HPC mixtures. Collectively, these results indicate that the IC HPC mixtures that were produced as a part of this study exhibit the potential of for substantially increased service life while markedly reducing the potential for early age cracking. The second phase of this thesis investigated the role of initial sample conditioning and the effect of changes in degree of saturation on the measured electrical resistivity, where a new function was developed to describe this relationship in air entrained concretes. The consistency and variability in the determination of the chloride diffusion coefficient was investigated through standardized testing methods, where it was shown that the coefficient of variation associated with the accelerated tests was approximately 15% or less and are dependent on the test. Chloride profile measurements made on cores taken from samples which were exposed with a known deicing solution and the temperature fluctuations of West Lafayette, Indiana indicated that on average, the coefficient of variation for determining the apparent chloride diffusion coefficient under is 30% or less. In addition, the use of resistivity measurements on sealed samples was used to evaluate the variability of the concrete produced throughout the construction of the fifth IC HPC bridge deck while comparisons of the samples from the first four bridge decks produced in the laboratory and in the field were also made. The results indicated that the coefficient of variation associated with the resistivity measurements made on the fifth bridge deck was less than 5%, while experimental results indicated that industrial production consistently results in lower performance as measured by the resistivity test when compared to laboratory production. In this study it was also shown that measurements of mechanical properties are not indicative of the potential durability of the concrete. The conclusions of this thesis and the findings presented in the FHWA/IN/JTRP-2010/10 report (Schlitter, Henkensiefken, et al. 2010) and the CDOT-2014-3 report (Jones et al. 2014) indicate that internal curing is a practice-ready, engineered solution that may lead to the production of higher performance concretes which have a reduced potential for cracking. To aid in the implementation of internal curing in practice, spreadsheets which automate calculations necessary for quality control for lightweight aggregates, mixture proportioning, and moisture adjustments have been developed by Miller (2014) and have been made available with the report documenting the construction of the first four bridge decks (Barrett et al. 2015). This thesis also provided the framework for a durability based design approach using sealed electrical resistivity measurements which may be implemented in practice. This method has been shown to be a viable way to rapidly evaluate the chloride diffusion coefficient of concrete and is appropriate for testing large numbers of samples during construction. It is recommended that the approach outlined in this work be implemented in performance based specifications in lieu of other accelerated testing methods which define the performance of the concrete based on the result of that test. Finally, it should be emphasized that the implementation of technologies such as those that are presented in this thesis alone does not guarantee higher performance, as the production of such concrete requires a degree of technical competence in design, production, and construction of concrete materials. As is the case with the production of any concrete, internally cured or not, performance will be directly tied to the careful accounting of water, be it on the surface of aggregates, in the mixing drum after washing, or elsewhere. Special attention should be paid to the proper operation of batching systems, while placement techniques should be reviewed to minimize unwanted effects, and proper finishing and curing techniques must always be practiced. Only after performing the basics of concrete production properly will the full benefits of internal curing be actualized.


Transverse Cracking of High Performance Concrete Bridge Decks After One Season Or Six to Eight Months

Transverse Cracking of High Performance Concrete Bridge Decks After One Season Or Six to Eight Months
Author:
Publisher:
Total Pages: 112
Release: 2006
Genre: Concrete
ISBN:

Download Transverse Cracking of High Performance Concrete Bridge Decks After One Season Or Six to Eight Months Book in PDF, ePub and Kindle

Cracking is a major problem with newly placed concrete decks. These decks tend to develop full depth, transverse cracks and partial depth longitudinal cracks within a few months of the concrete being placed. A literature review showed that several other states had experienced similar problems. A review of data from Ohio bridge decks showed weak correlations between deck cracking and slump, time of year when the deck was placed, shrinkage, chloride permeability and compressive strength, but there was no clear relationship between cracking and any of these properties. Data also suggested that using a coarse aggregate with an absorption> 1% may help mitigate deck cracking but will not always stop it. As part of this study, 3 bridge decks were instrumented. One was a standard class "S" concrete deck and the other two were high performance concrete. The class "S" deck showed only hairline cracking after 1 year, but transverse cracking occurred in the HPC decks. Instruments were placed in the decks to monitor strains. From the data, it appears that cracking is caused by several factors. High heat of hydration caused the plastic concrete to expand. When the concrete sets and cools, tensile stressed develop. Further tensile stresses develop through drying shrinkage. Restraining the deck against normal thermal movement contributes to additional tensile stress. Autogeneous shrinkage, where high heats of hydration cause water evaporation during hydration, and plastic shrinkage may cause more tensile stress. Recommendations for mitigating cracking include using lower cement contents, adding pozzolans and retarders, using slightly higher water/cement ratios, using larger aggregates, taking steps to limit shrinkage and eliminating restraints.


Investigation Into Shrinkage of High-Performance Concrete Used for Iowa Bridge Decks and Overlays

Investigation Into Shrinkage of High-Performance Concrete Used for Iowa Bridge Decks and Overlays
Author: Kejin Wang
Publisher:
Total Pages: 0
Release: 2013
Genre:
ISBN:

Download Investigation Into Shrinkage of High-Performance Concrete Used for Iowa Bridge Decks and Overlays Book in PDF, ePub and Kindle

High-performance concrete (HPC) overlays have been used increasingly as an effective and economical method for bridge decks in Iowa and other states. However, due to its high cementitious material content, HPC often displays high shrinkage cracking potential. This study investigated the shrinkage behavior and cracking potential of the HPC overlay mixes commonly used in Iowa. In the study, 11 HPC overlay mixes were studied. These mixes consisted of three types of cements (Type I, I/II, and IP) and various supplementary cementitious materials (Class C fly ash, slag and metakaolin). Limestone with two different gradations was used as coarse aggregates in 10 mixes and quartzite was used in one mix. Chemical shrinkage of pastes, free drying shrinkage, autogenous shrinkage of mortar and concrete, and restrained ring shrinkage of concrete were monitored over time. Mechanical properties (such as elastic modulus and compressive and splitting tensile strength) of these concrete mixes were measured at different ages. Creep coefficients of these concrete mixes were estimated using the RILEM B3 and NCHRP Report 496 models. Cracking potential of the concrete mixes was assessed based on both ASTM C 1581 and simple stress-to-strength ratio methods. The results indicate that among the 11 mixes studied, three mixes (4, 5, and 6) cracked at the age of 15, 11, and 17 days, respectively. Autogenous shrinkage of the HPC mixes ranges from 150 to 250 microstrain and free dying shrinkage of the concrete ranges from 700 to 1,200 microstrain at 56 days. Different concrete materials (cementitious type and admixtures) and mix proportions (cementitious material content) affect concrete shrinkage in different ways. Not all mixes having a high shrinkage value cracked first. The stresses in the concrete are associated primarily with the concrete shrinkage, elastic modulus, tensile strength, and creep. However, a good relationship is found between cementitious material content and total (autogenous and free drying) shrinkage of concrete.


Evaluation of Concrete Deck Curing Regimens Using Capillary Pressure Sensing System

Evaluation of Concrete Deck Curing Regimens Using Capillary Pressure Sensing System
Author: Samuel Spann
Publisher:
Total Pages: 66
Release: 2019
Genre: Concrete
ISBN:

Download Evaluation of Concrete Deck Curing Regimens Using Capillary Pressure Sensing System Book in PDF, ePub and Kindle

Early-age plastic shrinkage cracking is a common problem with the construction of concrete bridge decks due to the high surface area-to-volume ratio and exposure to potentially detrimental environmental effects. Curing regimens are utilized to mitigate cracking risk during the plastic stage of the concrete; the curing regimens evaluated for this study were wet burlap-polyethylene sheeting, two acrylic curing compounds, and one lithium compound. Capillary pressure in the water filled pores has been shown to correlate to the plastic shrinkage cracking risk of concrete. A new portable system has been developed to measure the capillary pressure that could potentially be used in the field on fresh bridge deck concrete. Individual test slabs were performed to test the curing regimens using the capillary pressure sensor system (CPSS). The system contains multiple sensors that contain pressure transducers that measure the capillary pressure changes during the plastic stage. Overall, wet burlap-polyethylene sheeting was shown to be the most effective curing regimen, with the lithium curing compound performing similarly to the control slab with no curing regimen applied. Both acrylic compounds were shown to perform comparatively well, completely mitigating early-age plastic shrinkage cracking in some instances, and allowing small shrinkage cracks to form in others. While the CPSS exhibited the ability to show when cracking occurred in most cases, the magnitude of the capillary pressure at which plastic shrinkage cracks formed varied significantly across tests.


Development and Layout of a Protocol for the Field Performance of Concrete Deck and Crack Sealants

Development and Layout of a Protocol for the Field Performance of Concrete Deck and Crack Sealants
Author: José Antonio Pincheira
Publisher:
Total Pages: 62
Release: 2009
Genre: Concrete bridges
ISBN:

Download Development and Layout of a Protocol for the Field Performance of Concrete Deck and Crack Sealants Book in PDF, ePub and Kindle

The main objective of this project was to develop and layout a protocol for the long-term monitoring and assessment of the performance of concrete deck and crack sealants in the field. To accomplish this goal, a total of six bridge decks were chosen for study. The decks have ages that vary from 4 to 30 years old, are all in good condition, though some presented a variety of longitudinal, transverse and diagonal cracking. In each deck, test segments were laid out along one lane in four of the six bridges. Drill powder samples were extracted in each segment in order to determine the in-situ, near-surface chloride ion content of the deck. Laboratory analyses of the samples showed that the chloride ion content varied between 3.2 lb/cy for the younger decks (3 years old) and 20.8 lb/cy for the older decks (28 years old). Based on the recommendations of a previous laboratory investigation, a pool of the best performing deck and crack sealants were selected to be applied in the decks. In two bridges, deck segments were sealed with four deck sealants while one segment was left unsealed to be used as a control segment. Additionally, the cracks in each of these segments were sealed with five crack sealants. While two other decks were also scheduled for sealing as part of this phase of the project, they were not done because the required curing time for some of the products was longer than deemed acceptable by DOT crews for these high traffic bridges. It is recommended, however, that every effort be made to have these decks be sealed in the near future. The remaining two bridges had been sealed at the time of construction. While no specific information could be secured about the product used in these decks, the low chloride ion content in these decks suggested that the applied product has helped reduce the ingress of chloride ions. Therefore, it is recommended that these decks continue to be monitored over time. Based on the inspections and the data collected in the field, a protocol and schedule for the continuing monitoring of sealant performance is presented.


Shrinkage Study of High Performance Concrete for Bridge Decks

Shrinkage Study of High Performance Concrete for Bridge Decks
Author: Tengfei Fu
Publisher:
Total Pages: 109
Release: 2013
Genre: High strength concrete
ISBN:

Download Shrinkage Study of High Performance Concrete for Bridge Decks Book in PDF, ePub and Kindle

In the field of civil infrastructure, bridge desks are typically constructed using high performance concrete (HPC). Concrete bridge decks demand qualities such as low permeability, high abrasion resistance, superior durability, and long design life. Over decades of field and laboratory experience, many HPC bridge decks have been found to be susceptible to shrinkage and subsequent cracking, which is regarded as a significant cause for premature deterioration, increased maintenance costs and even structural deficiency. Appropriate shrinkage limits and standard laboratory/field tests that allow proper criteria to ensure crack resistant HPC are not clearly established either in the technical literature or in specifications. A comprehensive study is presented in this dissertation on shrinkage and shrinkage induced cracking in HPC, with four main objectives: 1) mitigate the shrinkage and cracking issues in HPC using internal curing by fine lightweight aggregate (FLWA) and/or incorporation of shrinkage reducing admixture (SRA); 2) improve the standard ASTM chemical shrinkage test method for HPC systems containing supplementary cementitious materials (SCMs) and/or SRA; 3) modify existing drying shrinkage models mainly the ACI 209 model to predict long-term drying shrinkage for modern HPC concrete by using short-term experimental measurements; 4) complete a state-of-the-art literature review on shrinkage and cracking issues in HPC bridge decks. One of the most significant research findings is a proposed "cracking potential indicator" (CPI) that uses only the free shrinkage and mechanical properties of HPC. This was correlated to standard restrained ring tests.