Field Evaluation Of A Passive Sampling Device For Hydrazines In Ambient Air PDF Download

Are you looking for read ebook online? Search for your book and save it on your Kindle device, PC, phones or tablets. Download Field Evaluation Of A Passive Sampling Device For Hydrazines In Ambient Air PDF full book. Access full book title Field Evaluation Of A Passive Sampling Device For Hydrazines In Ambient Air.

Field Evaluation of a Passive Sampling Device for Hydrazines in Ambient Air

Field Evaluation of a Passive Sampling Device for Hydrazines in Ambient Air
Author: P. A. Taffe
Publisher:
Total Pages: 93
Release: 1990
Genre:
ISBN:

Download Field Evaluation of a Passive Sampling Device for Hydrazines in Ambient Air Book in PDF, ePub and Kindle

A passive sample-dosimeter has been developed for evaluating part-per billion (ppb) levels of hydrazine and monomethyl hydrazine (MMH) in ambient air. It is designed for quantitative documentation of personnel exposures as well as ambient atmosphere concentration. It has undergone extensive laboratory and field evaluations. The laboratory tests are reviewed in this report. Tests were conducted in controlled atmospheres to evaluate the following performance parameters: collection rate, face velocity, relative humidity effects, sample stability, reproducibility, linearity, and interference effects of selected chemical vapors. Field tests were conducted to evaluate performance under typical anticipated conditions. The test locations were selected to provide information on the probable interferents. A double-bind protocol was used which involved three groups: industrial hygienists; analytical chemists; and auditors. The data obtained from the field evaluation disclosed a performance problem not encountered in the laboratory. The cause was identified and the prototype system was modified and re-tested. The results from the modified sampler indicate that it is suitable for work place monitoring applications with two minor interferents: tobacco smoke and intense direct sunlight. Threshold Limit Value (TLV), Monomethyl hydrazine, Hydrazine, Radiobiology, Dimethylhydrazine, Dosimetry, Vapor detection, Environmental tests. (JG).


Laboratory Development of a Passive Sampling Device for Hydrazines in Ambient Air

Laboratory Development of a Passive Sampling Device for Hydrazines in Ambient Air
Author: P. A. Taffe
Publisher:
Total Pages: 23
Release: 1990
Genre:
ISBN:

Download Laboratory Development of a Passive Sampling Device for Hydrazines in Ambient Air Book in PDF, ePub and Kindle

A passive sampling method applicable to personnel and area monitoring has been developed for the quantitation of hydrazine, monomethylhydrazine (MMH), and unsymmetrical dimethylhydrazine (UDMH) in ambient air at the part-per-billion (ppb) level. The method uses a black molded low density polyethylene badge consisting of a diffusion barrier and a citric acid collection medium. It collects samples that can be analyzed by the NIOSH colorimetric method or a coulometric titration procedure. The two millimeter thick diffusion barrier contains 144 one millimeter diameter holes and produces a collection rate for MMH of approximately 27 ml/min. The accuracy of data collected with this badge is within 30% of actual values. The dosimeter has demonstrated accuracy for sampling periods of 15 minutes to 66 hours, when sampling MMH at the threshold limit value (TLV) concentration of 200 ppb. The limits of detection are dictated by the specific analytical method. Coulometric titration will detect exposures of 30 ppb-hours. An evaluation of the effects of face velocity, relative humidity, and potential interferences was conducted. (jes).


Passive Sampling Techniques in Environmental Monitoring

Passive Sampling Techniques in Environmental Monitoring
Author: Richard Greenwood
Publisher: Elsevier
Total Pages: 487
Release: 2007-07-03
Genre: Science
ISBN: 0080489508

Download Passive Sampling Techniques in Environmental Monitoring Book in PDF, ePub and Kindle

Monitoring pollutants in air, soil and water is a routine requirement in the workplace, and in the wider environment. Passive samplers can provide a representative picture of levels of pollutants over a period of time from days to months by measuring the average concentrations to which they have been exposed. Air monitors are widely used, for instance to measure the exposure of workers to volatile compounds, but also for monitoring the fate of pollutants in the atmosphere. Passive sampling devices are now becomining increasingly used to monitor pollutants in rivers, coastal waters and ground water where contamination results from sources such as domestic and industrial discharges, and the use of agrochemicals. Passive Sampling Techniques in Environmental Monitoring provides a timely collection of information on a set of techniques that help monitor the quality of air, surface and ground waters. Passive sampling can provide an inexpensive means of obtaining a representative picture of quality over a period of time, even where levels of pollutants fluctuate due to discontinuous discharges or seasonal application of chemicals such as pesticides. Recent changes in legislation have increased the pressure to obtain better information than that provided by classical infrequent spot sampling.Brought together in one source, this book looks at the performance of a range of devices for the passive sampling of metals, and of non-polar and polar organic chemicals in air and in water. The strengths and weaknesses and the range of applicability of the technology are considered. * Comprehensive review of passive sampling - covering air, water and majority of available technologies in one volume* Chapters written by international specialist experts * Covers theory and applications, providing background information and guidelines for use in the field


Energy Research Abstracts

Energy Research Abstracts
Author:
Publisher:
Total Pages: 712
Release: 1990
Genre: Power resources
ISBN:

Download Energy Research Abstracts Book in PDF, ePub and Kindle


Government Reports Annual Index

Government Reports Annual Index
Author:
Publisher:
Total Pages: 1120
Release: 1990
Genre: Government publications
ISBN:

Download Government Reports Annual Index Book in PDF, ePub and Kindle


Development and Evaluation of Passive Sampling Devices to Characterize the Sources, Occurrence, and Fate of Polar Organic Contaminants in Aquatic Systems

Development and Evaluation of Passive Sampling Devices to Characterize the Sources, Occurrence, and Fate of Polar Organic Contaminants in Aquatic Systems
Author: Jonathan K. Challis
Publisher:
Total Pages: 0
Release: 2018
Genre:
ISBN:

Download Development and Evaluation of Passive Sampling Devices to Characterize the Sources, Occurrence, and Fate of Polar Organic Contaminants in Aquatic Systems Book in PDF, ePub and Kindle

The primary goal of this dissertation was to develop and evaluate an improved aquatic passive sampling device (PSD) for measurement of polar organic contaminants. Chemical uptake of current polar-PSDs (e.g., POCIS - polar organic chemical integrative sampler) is dependent on the specific environmental conditions in which the sampler is deployed (flow-rate, temperature), leading to large uncertainties when applying laboratory-derived sampling rates in-situ. A novel configuration of the diffusive gradients in thin-films (DGT) passive sampler was developed to overcome these challenges. The organic-DGT (o-DGT) configuration comprised a hydrophilic-lipophilic balance® sorbent binding phase and an outer agarose diffusive gel (thickness = 0.5-1.5 mm), notably excluding a polyethersulfone protective membrane which is used with all other polar-PSDs. Sampler calibration exhibited linear uptake and sufficient capacity for 34 pharmaceuticals and pesticides over typical environmental deployment times, with measured sampling rates ranging from 9-16 mL/d. Measured and modelled diffusion coefficients (D) through the outer agarose gel provided temperature-specific estimates of o-DGT sampling rates within 20% (measured-D) and 30% (modelled-D) compared to rates determined through full-sampler calibration. Boundary layer experiments in lab and field demonstrated that inclusion of the agarose diffusive gel negated boundary layer effects, suggesting that o-DGT uptake is largely insensitive to hydrodynamic conditions. The utility of o-DGT was evaluated under a variety of field conditions and performance was assessed in comparison to POCIS and grab samples. o-DGT was effective at measuring pharmaceuticals and pesticides in raw wastewater effluents, small creeks, large fast-flowing rivers, open-water lakes, and under ice at near-zero water temperatures. Concentrations measured by o-DGT were more accurate than POCIS when compared to grab samples, likely resulting from the influence in-situ conditions have on POCIS. Modelled sampling rates were successfully used to estimate semi-quantitative water concentrations of suspect wastewater contaminants using high-resolution mass spectrometry, demonstrating the unique utility of this o-DGT technique. This dissertation establishes o-DGT as a more accurate, user-friendly, and widely applicable passive sampler compared to current-use polar-PSDs. The o-DGT tool will help facilitate more accurate and efficient monitoring efforts and ultimately lead to more appropriate exposure data and environmental risk assessment.