Development Of A Tunable Diode Laser Absorption Spectroscopy Technique For Application To Tomographic Measurements In Scramjets PDF Download

Are you looking for read ebook online? Search for your book and save it on your Kindle device, PC, phones or tablets. Download Development Of A Tunable Diode Laser Absorption Spectroscopy Technique For Application To Tomographic Measurements In Scramjets PDF full book. Access full book title Development Of A Tunable Diode Laser Absorption Spectroscopy Technique For Application To Tomographic Measurements In Scramjets.

Advances in Tunable Diode Laser Spectroscopy for Aero Engine Research

Advances in Tunable Diode Laser Spectroscopy for Aero Engine Research
Author: Thomas Benoy
Publisher:
Total Pages: 0
Release: 2016
Genre:
ISBN:

Download Advances in Tunable Diode Laser Spectroscopy for Aero Engine Research Book in PDF, ePub and Kindle

Tunable diode laser spectroscopy (TDLS) is a widely used technique for the measurement of gas species and offers in-situ operation, accuracy and faster response time compared to other optical and non-optical gas sensing techniques.The work in this thesis focusses on the measurement of CO2 in the harsh environment of a gas turbine engine (GTE). The work is part of a much larger initiative called Fibre Laser Imaging of gas Turbine Exhaust Species (FLITES) aimed at obtaining concentration distributions of gas species such as CO2 and NO, unburnt hydrocarbons, and soot in a gas turbine exhaust plume using optical tomography. In the FLITES system, a thulium doped fibre amplifier (TDFA) is used to boost the optical power output from a 2 mW, 1997 nm, multi-quantum well distributed feedback (DFB-MQW) laser to feed 126 measurement channels arranged in dodecagon geometry for optical tomography. Hence, agile TDLS techniques need to be developed which can be scaled up to the multi-channel measurement system.Attributed by the interference from noise in the measurement environment of a GTE, phase sensitive detection using a lock-in amplifier (LIA) has to be employed where an additional current modulation is applied to the DFB laser, creating an instantaneous intensity modulated output and a delayed wavelength modulation (WM) output. This technique falls under a metrology branch known as wavelength modulation spectroscopy (WMS).The unknown measurement conditions expected in a GTE engine necessitates the use of calibration-free WMS techniques for the simultaneous measurement of gas concentration and temperature. Calibration-free techniques in WMS have been developed at the Centre for Microsystems and Photonics (CMP) of Strathclyde University. These are known as the phasor decomposition method (PDM) and the residual amplitude modulation (RAM) technique. They employ the signals obtained using the first harmonic demodulation of the WMS signals, followed by post processing to recover the gas absorption line shape. It was known in the CMP group that the accuracy of these techniques was limited by the variation in the laser modulation parameters such as the phase of the wavelength modulation relative to the intensity modulation (WM-IM phase lag) and the wavelength modulation amplitude across the laser current scan.The solutions to two problems are addressed in this thesis, viz. the implementation of correction procedures to account for the variation in the laser modulation parameters across the current scan and the need for a calibration-free technique for the measurement of CO2 in a GTE exhaust plume scalable to a multi-channel measurement system.Accurate measurements of the wavelength modulation parameters were made across the current scan and correction algorithms were implemented to compensate for its effects on the recovered gas absorption line shape.The gas spectral parameters were measured in the lab for the R48 absorption line of CO2 near 1997.2 nm at the higher temperatures (up to 500°C) expected in a GTE exhaust plume, using a heated gas cell. A Fourier expansion model was developed for the WMS signals which employ the measured laser modulation and gas spectral parameters. 1f normalised 2f WMS technique was chosen as the calibration-free measurement approach due to the advantages of cancellation of the transmission fluctuations as well as signal normalisation. The 2f/1f measurement technique was validated in the lab at higher temperatures for the simultaneous recovery of the CO2 concentration and temperature with an accuracy of 3.39 % and 3.72 %, respectively. Subsequently, field campaigns were conducted at the Rolls-Royce test facility at East Kilbride, yielding concentration and temperature values having good correlation to the engine operating conditions such as the throttle and core temperature.Multi-channel tomographic measurements were conducted on the test phantoms at INTA, Madrid, using TFLAS-WMS (tunable fibre laser absorption spectroscopy). Accurate concentration images could be recovered using tomographic reconstruction algorithms.


Progress in Combustion Diagnostics, Science and Technology

Progress in Combustion Diagnostics, Science and Technology
Author: Paul Medwell
Publisher: MDPI
Total Pages: 336
Release: 2020-03-25
Genre: Technology & Engineering
ISBN: 3039285106

Download Progress in Combustion Diagnostics, Science and Technology Book in PDF, ePub and Kindle

The role that combustion plays in the world’s energy systems will continue to evolve with the changes in technological demands. For example, the challenges that we face today are more focused on the conservation of energy and addressing environmental concerns, which together necessitate cleaner and more efficient combustion processes using a range of fuel sources. This book includes contributions to highlight the recent progress in theory and experiments, development, and demonstration of technologies and systems involving combustion processes, for the production, storage, use, and conservation of energy.


Industrial Applications of Tunable Diode Laser Absorption Spectroscopy

Industrial Applications of Tunable Diode Laser Absorption Spectroscopy
Author: Zhenzhen Wang
Publisher:
Total Pages:
Release: 2018
Genre: Technology
ISBN:

Download Industrial Applications of Tunable Diode Laser Absorption Spectroscopy Book in PDF, ePub and Kindle

Tunable diode laser absorption spectroscopy (TDLAS) utilizes the absorption phenomena to measure the temperature and species concentration. The main features of the TDLAS technique are its fast response and high sensitivity. Extensive research has been performed on the utilization of diode laser absorption spectroscopy for the system monitoring and its control. The TDLAS technique gives self-calibrations to reduce the noise such as particles and dusts because the laser wavelength is rapidly modulated at kHz rates. In addition, two dimensional (2D) temperature and concentration distributions can be obtained by combining computed tomography (CT) with TDLAS. The TDLAS applications have been extensively studied with great progress. This chapter largely focuses on the engineering fields, especially the practical industrial applications.


Tunable Diode Laser Absorption Spectrometry for Ultra-Trace Measurement and Calibration of Atmospheric Constituents

Tunable Diode Laser Absorption Spectrometry for Ultra-Trace Measurement and Calibration of Atmospheric Constituents
Author: A. Fried
Publisher:
Total Pages: 11
Release: 1985
Genre: Air quality
ISBN:

Download Tunable Diode Laser Absorption Spectrometry for Ultra-Trace Measurement and Calibration of Atmospheric Constituents Book in PDF, ePub and Kindle

There has been an ongoing quest for development of ever more sensitive and selective detection methods for studying various gas molecules of atmospheric importance. Both laboratory and ambient studies often require instrumentation capable of measuring ultratrace concentrations of such gases at, and below, the parts-per-billion range. Concurrently, accurate calibration standards, particularly those verified by independent techniques, are also required. The sensitive, selective, and versatile technique of infrared tunable diode laser absorption spectrometry is especially well suited for ultra-trace gas measurements and calibration standards verification. This combination, which is not shared by many other measurement techniques, results from the fact that diode laser spectrometers can be operated in an absolute mode as well as a more sensitive relative mode. In this paper, we discuss these capabilities and present specific examples for the measurement and calibration of ultra-trace levels of the important atmospheric gases nitrogen dioxide (NO2) and hydrochloric acid (HCl). In addition, we further discuss the application of tunable diode laser absorption spectrometry in the verification of NO2 permeation standards using the gas-phase titration reaction between nitric oxide (NO) and ozone (O3).


Near Infrared Tunable Diode Laser Spectroscopy for Aero Engine Related Applications

Near Infrared Tunable Diode Laser Spectroscopy for Aero Engine Related Applications
Author: James R. P. Bain
Publisher:
Total Pages: 0
Release: 2012
Genre:
ISBN:

Download Near Infrared Tunable Diode Laser Spectroscopy for Aero Engine Related Applications Book in PDF, ePub and Kindle

Tunable diode laser spectroscopy is a widely used technique for recovering quantitative gas information in a range of industrial applications. Established methods often use readily available, robust and low cost optoelectronic hardware in the near-infrared, with output wavelengths that coincide with the absorption spectra of several important gas species of interest, providing a versatile platform for gas analysis instrumentation. In this work the challenges associated with the recovery of gas information from harsh detection environments, particularly for aero engine diagnostics, are considered. For stand-alone instrumentation, calibration-free direct absorption measurements are highly advantageous yet calibrated techniques employing wavelength modulation spectroscopy are often favoured due to their significantly higher sensitivities. Recent developments have enabled calibration-free line shape recovery using lock-in amplifier detection of the residual amplitude modulation in wavelength modulated signals. These techniques have significant potential in harsh environments, but the overall sensitivity is limited by distortions to the recovered line shapes at high modulation amplitudes and by large background signals that saturate the detection electronics. In this thesis, solutions to these two problems are proposed, investigated and validated. A correction function is derived that is able to account for line shape distortions at arbitrarily high modulation indices. Application of the function depends upon knowledge of the experimental modulation index and two methods for extracting this information directly from the experimental signals are described. The full correction procedure has been experimentally validated. An investigation was made into the use of autobalanced photoreceivers, typically used for common mode noise cancellation, for direct absorption measurements and in a different configuration for nulling of the residual amplitude modulation (RAM) in wavelength modulation spectroscopy. Initial measurements suggest that removal of the background RAM can increase the lock-in detection sensitivity by over an order of magnitude. In addition an external amplitude modulator has been iv shown to be an effective method for producing sensitive absorption signals that are free of distortions, recoverable at frequencies that are outside the bandwidth of most environmental noise sources. A temperature sensor based on ratio thermometry of ambient water vapour absorption was designed and evaluated. The sensor is intended to provide accurate intake gas temperature information during aero engine ground testing when misting conditions prevent standard thermocouples from providing reliable data. Direct detection and second harmonic wavelength modulation spectroscopy experiments were undertaken in an environmental chamber, over the range 273-313K, to test the potential accuracy of the proposed system. Using a second harmonic peak height method, temperature information based on a calibration was able to recover temperature measurements with precision of ±0.4K however the overall accuracy suffered from a problematic calibration drift. Three engine test campaigns are described in which a range of recovery methods and potential optical system layouts are evaluated for the purposes of intake and exhaust mounted test bed sensor systems. The effects of extreme noise conditions were observed on a variety of measurements and favourable detection and modulation options were identified for the purpose of planning proposed future engine tests. Exhaust plume measurements of high temperature water vapour on the Rolls-Royce Environmentally Friendly Engine demonstrator established the viability of temperature and concentration measurements up to 850K.


Precision Spectroscopy, Diode Lasers, and Optical Frequency Measur

Precision Spectroscopy, Diode Lasers, and Optical Frequency Measur
Author: Leo Hollberg
Publisher: DIANE Publishing
Total Pages: 293
Release: 2000
Genre:
ISBN: 0788186140

Download Precision Spectroscopy, Diode Lasers, and Optical Frequency Measur Book in PDF, ePub and Kindle

A selected set of reprints from the Optical Frequency Measurement Group of the Time and Frequency Div. of the Nat. Inst. of Standards and Technology and consists of work published between 1987 and 1997. The 2 programs represented are (1) development of tunable diode-laser technology for scientific applications and precision measurements, and (2) research toward the goal of realizing optical-frequency measurements and synthesis. The papers are organized in 5 categories: diode laser technology; tunable laser systems; laser spectroscopy; optical synthesis and extended wavelength coverage; and multi-photon interactions and optical coherence.